    Technical Documents

  • Download .pdf document of this AFCI requirement page which shows the dates and locations for which arc-fault circuit interupter (AFCI) protection was required by the National Electrical Code (NEC) for Dwelling Units








  • Compiled by Jerry Peck © Copyright 1999-2008 Jerry Peck
    DWELLING UNIT
    120 volt AFCI Protected Receptacle Outlets - REQUIRED LOCATIONS
    DATE
    OF
    NEC
    EDITION
    B
    E
    D
    R
    O
    O
    M
    S
    F
    A
    M
    I
    L
    Y

    R
    O
    O
    M
    S
    D
    I
    N
    I
    N
    G

    R
    O
    O
    M
    S
    L
    I
    V
    I
    N
    G

    R
    O
    O
    M
    S
    P
    A
    R
    L
    O
    R
    S
    L
    I
    B
    R
    A
    R
    I
    E
    S
    D
    E
    N
    S
    S
    U
    N
    R
    O
    O
    M
    S
    R
    E
    C
    R
    E
    A
    T
    I
    O
    N

    R
    O
    O
    M
    S
    C
    L
    O
    S
    E
    T
    S
    H
    A
    L
    L
    W
    A
    Y
    S
    S
    I
    M
    I
    L
    A
    R
    R
    O
    O
    M
    S
    A
    R
    E
    A
    S
    1999
    X1a
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    2002
    X1b
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    2005
    X1b
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    2008
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c
    X1c

    • X1a = All 120-volt 15 and 20 amp branch circuits supplying RECEPTACLE OUTLETS in all bedrooms, i.e., AFCI is at breaker panel - Effective Date is January 1, 2002.


    • X1b = All 120-volt 15 and 20 amp branch circuits supplying ALL OUTLETS in all bedrooms, i.e., AFCI is at breaker panel.


    • X1c = All 120-volt 15 and 20 amp branch circuits supplying ALL OUTLETS in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or area, i.e., AFCI is at breaker panel - EXCEPT:


      • Exception 1 Where rigid conduit, intermediate conduit, EMT, or Type AC steel armored cable using metal outlet and junction boxes is used between the breaker and the first receptacle of a circuit, the AFCI device is permitted to be installed at the first outlet in the circuit.


      • Exception 2 Power limited fire alarm circuits provided those circuits are installed in rigid conduit, intermediate conduit, EMT, or Type AC steel armored cable using metal outlet and junction boxes - no AFCI protection is required. This exception will rarely be applicable for dwelling units.


    © Copyright 2008 JerryPeck